- | The Sterling BBS1230 Pro Batt Ultra is a 30A boost/buck 30A charger. [[https://www.12voltplanet.co.uk/user/downloads/ | + | {{ https://external-content.duckduckgo.com/iu/?u=https%3A%2F%2Ftse1.mm.bing.net%2Fth%3Fid%3DOIP.XpvtZUxAsHhAUuiFBNLfFAHaG2%26pid%3DApi& |
+ | The Sterling BBS1230 Pro Batt Ultra is a 30A boost/buck 30A charger. The solar input max is 31V and 16A. Alternator input voltage is 11v-20v and 30A. Both the solar and b2b charging can be turned off separately. | ||
- | solar+alternator behavior | + | [[https:// |
+ | === solar+alternator behavior === | ||
+ | The charger charges only from alternator when engine is running: | ||
+ | |||
+ | > When your engine is running, the BB aspect of the BBS charges. When the engine / ignition is off, the solar charger works. They do not work simultaneously. | ||
+ | |||
+ | |||
+ | === starter battery maintenance behavior === | ||
the manual for the pre-2022 version incorrectly claims the unit maintains the starter battery. | the manual for the pre-2022 version incorrectly claims the unit maintains the starter battery. |