-==== equalization stage ====+==== equalization ====
  
 Sometimes called the fourth stage, "equalizing is an overcharge performed after fully charging deep-cycle flooded/wet batteries. An equalizing charge prevents battery stratification and reduces sulfation which are leading causes of battery failure. Trojan recommends equalizing every 30 days or when batteries have a low specific gravity reading after fully charging... Deep-cycle AGM or gel batteries should NEVER be equalized."((http://www.trojanbattery.com/pdf/TrojanBattery_UsersGuide.pdf)) Sometimes called the fourth stage, "equalizing is an overcharge performed after fully charging deep-cycle flooded/wet batteries. An equalizing charge prevents battery stratification and reduces sulfation which are leading causes of battery failure. Trojan recommends equalizing every 30 days or when batteries have a low specific gravity reading after fully charging... Deep-cycle AGM or gel batteries should NEVER be equalized."((http://www.trojanbattery.com/pdf/TrojanBattery_UsersGuide.pdf))
 +
 +House banks in rigs that are driven regularly are likely already mixed by jostling, so equalization may be less important.
  
 Our theoretical T-105 bank will equalize at 16.2v.  Since voltages are so high **it is common to disconnect everything else from the battery during equalization**;  this prevents overvoltage damage to electronics.  Overvolting electronics could be particularly expensive if the solar controller goes into equalization when [[electrical:12v:alternator|alternator charging]] is occuring -- the [[electrical:12v:intro|house]] and [[electrical:12v:chassis_power|chassis]] sytems are combined and overvoltage could be sent back to the vehicle. Our theoretical T-105 bank will equalize at 16.2v.  Since voltages are so high **it is common to disconnect everything else from the battery during equalization**;  this prevents overvoltage damage to electronics.  Overvolting electronics could be particularly expensive if the solar controller goes into equalization when [[electrical:12v:alternator|alternator charging]] is occuring -- the [[electrical:12v:intro|house]] and [[electrical:12v:chassis_power|chassis]] sytems are combined and overvoltage could be sent back to the vehicle.
  
  
-Water levels should be topped off //after// equalization. Doing so before equalization could result in spillover.+Water levels should be topped off //after// equalization.((exposed plates should be covered before EQ, though)) Doing so before equalization could result in spillover.
  
  