electrical:12v:charging [2020/01/07 22:16] frater_secessus [absorption stage] |
electrical:12v:charging [2020/01/13 10:39] frater_secessus [absorption stage] |
The absorption stage, sometimes called //acceptance//((which makes sense)) or //boost//((doesn't make sense!)), is a constant voltage stage during which the battery is brought to full charge. This stage requires a **great deal of time** but decreasing amounts of current. | The absorption stage, sometimes called //acceptance//((which makes sense)) or //boost//((doesn't make sense!)), is a constant voltage stage during which the battery is brought to full charge. This stage requires a **great deal of time** but decreasing amounts of current. |
| |
Absorption **begins when the battery reaches the absorption voltage** ([[electrical:12v:electrical notation|Vabs]], 14.8v in our example) and **ends when the battery tapers off current acceptance** to something like C/100 ("End Absorb", "endAmps"), and/or when a period of time has elapsed. In practice absorption takes longer when the battery has been discharged deeply and shorter when it has not.((http://www.cheaprvliving.com/forums/Thread-Can-a-solar-panel-and-charge-controller-over-charge-a-battery?pid=96965#pid96965)) | Absorption **begins when the battery reaches the absorption voltage** ([[electrical:12v:electrical notation|Vabs]], 14.8v in our example) and **ends when the battery tapers off current acceptance** to something like [[electrical:12v:battery_capacity|C/100]] ("End Absorb", "endAmps"), and/or when a period of time has elapsed. |
| |
| Example: if you have a 100Ah battery bank and the manufacturer states that endAmps is C/100, then the battery is fully charged when it is only accepting 1A of current((100Ah/100 = 1A)) **at Vabs**. An endAmps recommendation of C/200 would be the battery accepting 0.5A of current.((100Ah/200 = 0.5A)) at Vabs. |
| |
| |
| In practice absorption takes longer when the battery has been discharged deeply and shorter when it has not.((http://www.cheaprvliving.com/forums/Thread-Can-a-solar-panel-and-charge-controller-over-charge-a-battery?pid=96965#pid96965)) |
| |
Some controllers will allow the user to configure the time or ratio of capacity/current (C///n//). Sternwake says: | Some controllers will allow the user to configure the time or ratio of capacity/current (C///n//). Sternwake says: |