===== three stage charging ===== | ===== three stage charging ===== | ||
- | Three stage or " | + | Three stage((some mfg claim 4 or more charging stages, including equalization or proprietary stages. |
SternWake sums up smart charging: | SternWake sums up smart charging: | ||
- | > "Bulk rate is maximum amps the charging source can supply until the absorption voltage is reached, at that point the amps required to hold the ABSV will taper. The longer the battery is held at ABSV, the more the amps required to hold ABSV will taper. At some point, either time, or the amps required to hold ABSV fall below a threshold and triggers float mode." | + | > "Bulk rate is maximum amps the charging source can supply until the absorption voltage is reached, at that point the amps required to hold the ABSV((Vabs, absorption voltage)) |
Line 73: | Line 73: | ||
Common Vfloat values range between 13.2v for stored batteries to 13.8v for banks that are deep cycled each day. | Common Vfloat values range between 13.2v for stored batteries to 13.8v for banks that are deep cycled each day. | ||
+ | |||
+ | also see [[electrical: | ||