electrical:12v:directcharginglfp [2022/09/17 18:13]
frater_secessus [current drawn expressed as percentage of alternator rating]
electrical:12v:directcharginglfp [2022/09/17 18:14]
frater_secessus [failures]
Line 97: Line 97:
 === lessons === === lessons ===
  
-Don'direct-charge banks that have 2-3x the capacity of your alternator's rating.   Use [[electrical:12v:b2b|a DC-DC charger]], external regulation, or current reduction with resistance as described elsewhere in this article.+Think twice about  direct-charging banks that have 2-3x the capacity of your alternator's rating.   Use [[electrical:12v:b2b|a DC-DC charger]], external regulation, or current reduction with resistance as described elsewhere in this article.
  
 Do not idle to charge.  Do not idle to charge. 