electrical:12v:drop-in_lifepo4 [2022/09/15 17:52] frater_secessus [myth: if you don't charge to 14.4v the cells won't balance] |
electrical:12v:drop-in_lifepo4 [2022/09/15 18:28] frater_secessus [myth: lithium doesn't need absorption] |
||
---|---|---|---|
Line 189: | Line 189: | ||
+ | Lithium doesn' | ||
- | Lithium doesn' | + | Most charts and tables showing voltage v. SoC assume moderate rates of charge like 0.2[[electrical: |
+ | **Very high charge rates**, as sometimes seen with [[id=electrical: | ||
+ | One rule of thumb is that the bank is fully charged when you are at your target voltage and current acceptance has decreased to ≤0.10C. | ||
- | FIXME | ||
==== myth: you can't charge Li with a lead battery charger ==== | ==== myth: you can't charge Li with a lead battery charger ==== |