This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
electrical:12v:drop-in_lifepo4 [2022/09/15 18:02] frater_secessus [myth: lithium doesn't need absorption] |
electrical:12v:drop-in_lifepo4 [2022/09/15 18:29] frater_secessus [myth: lithium doesn't need absorption] |
||
---|---|---|---|
Line 191: | Line 191: | ||
Lithium doesn' | Lithium doesn' | ||
- | Most charts and tables showing voltage v. SoC assume moderate rates of charge like 0.2[[electrical: | + | Most charts and tables showing voltage v. SoC assume moderate rates of charge like 0.2[[electrical: |
+ | **Very high charge rates**, as sometimes seen with [[electrical: | ||
+ | One rule of thumb is that the bank is fully charged when you are at your target voltage and current acceptance has decreased to ≤0.10C. | ||
- | The chief factor that can affecting Abis high rates of charge. | ||
==== myth: you can't charge Li with a lead battery charger ==== | ==== myth: you can't charge Li with a lead battery charger ==== |