 Note:  this is for deep cycle lead chemistries only.!  Lithium chemistries should not be held at full voltage.  Note:  this is for deep cycle lead chemistries only.!  Lithium chemistries should not be held at full voltage. 
  
-====== insufficient Absorption ======+====== dealing with insufficient Absorption ======
  
 In off-grid solar charging scenarios batteries are most often damaged by [[electrical:batterycide|chronic undercharging]].  Specifically, not holding the [[electrical:solar:charge_controller_setpoints|manufacturer's recomended Absorption voltage]] (Vabs), and not holding that voltage long enough((duration)) for acceptance to drop to endAmps. In off-grid solar charging scenarios batteries are most often damaged by [[electrical:batterycide|chronic undercharging]].  Specifically, not holding the [[electrical:solar:charge_controller_setpoints|manufacturer's recomended Absorption voltage]] (Vabs), and not holding that voltage long enough((duration)) for acceptance to drop to endAmps.