electrical:12v:eternal_absorption [2020/07/08 12:08]
frater_secessus [insufficient Absorption]
electrical:12v:eternal_absorption [2020/07/08 12:10]
frater_secessus [set Vfloat to Vabs]
Line 13: Line 13:
 ===== set Vfloat to Vabs ===== ===== set Vfloat to Vabs =====
  
-The Eternal Absorption approach completely forgoes Float stage, forcing the controller to stay in Absorption by setting Vfloat to Vabs. This addresses the controller issues above.+The Eternal Absorption approach completely forgoes Float stage, forcing the controller to stay in Absorption by setting Vfloat to Vabs. This addresses the controller issues above.  It will not address the insolation problem on a given day, but extended Absorption will help reduce damage from previous days of poor harvest
  
  