This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
electrical:12v:eternal_absorption [2020/07/08 12:08] frater_secessus [insufficient Absorption] |
electrical:12v:eternal_absorption [2020/07/08 12:15] frater_secessus [dealing with insufficient Absorption] |
||
---|---|---|---|
Line 1: | Line 1: | ||
Note: this is for deep cycle lead chemistries only.! | Note: this is for deep cycle lead chemistries only.! | ||
+ | |||
+ | |||
+ | [[lifestyle: | ||
+ | |||
+ | > "As long as... you cycle the battery daily, you could set float voltage to [Vabs] too without worry. Only when you stop cycling the battery do you need to return float voltage to more regular 13.2v levels." | ||
+ | |||
====== dealing with insufficient Absorption ====== | ====== dealing with insufficient Absorption ====== | ||
Line 13: | Line 19: | ||
===== set Vfloat to Vabs ===== | ===== set Vfloat to Vabs ===== | ||
- | The Eternal Absorption approach completely forgoes Float stage, forcing the controller to stay in Absorption by setting Vfloat to Vabs. This addresses the controller issues above. | + | The Eternal Absorption approach completely forgoes Float stage, forcing the controller to stay in Absorption by setting Vfloat to Vabs. This addresses the controller issues above. It will not address the insolation problem on a given day, but extended Absorption will help reduce damage from previous days of poor harvest. |