electrical:12v:lvd [2018/06/23 16:44]
frater_secessus
electrical:12v:lvd [2018/06/23 16:45]
frater_secessus [common LVD setpoints]
Line 11: Line 11:
 ===== common LVD setpoints ===== ===== common LVD setpoints =====
  
-Lead-acid deep cycle batteries last the longest with best capacity if they are never cycled more than 50% [[electrical:depth_of_discharge|Depth of Discharge]]((and fully charged afterwards)).  That point is somewhere around 12.20v when rested or very lightly loaded.  Voltage //sags// under heavy load: +Lead-acid deep cycle batteries last the longest with best capacity if they are never cycled more than 50% [[electrical:depth_of_discharge|Depth of Discharge]]((and fully charged afterwards)).  That point is somewhere around 12.20v when rested or very lightly loaded.  
- +
-|  **State of Charge**|  **Voltage, light or no load((1.0 per Trojan))**|  **moderate load((interpolated))**|  **heavy load((per Trojan))**| +
-|  100|  12.70|  11.43|  10.16| +
-|  90|  12.60|  11.34|  10.08| +
-|  80|  12.40|  11.16|  9.92| +
-|  70|  12.30|  11.07|  9.84| +
-|  60|  12.20|  10.98|  9.76| +
-|  50|  12.10|  10.89|  9.68| +
-|  40|  12.00|  10.80|  9.60| +
-|  30|  11.80|  10.62|  9.44| +
-|  20|  11.65|  10.49|  9.32|+
  
  
electrical/12v/lvd.txt · Last modified: 2023/09/06 10:54 by frater_secessus