This shows you the differences between two versions of the page.
Both sides previous revision Previous revision | Next revision Both sides next revision | ||
electrical:12v:lvd [2018/06/23 16:44] frater_secessus |
electrical:12v:lvd [2018/06/23 16:45] frater_secessus [common LVD setpoints] |
||
---|---|---|---|
Line 11: | Line 11: | ||
===== common LVD setpoints ===== | ===== common LVD setpoints ===== | ||
- | Lead-acid deep cycle batteries last the longest with best capacity if they are never cycled more than 50% [[electrical: | + | Lead-acid deep cycle batteries last the longest with best capacity if they are never cycled more than 50% [[electrical: |
- | + | ||
- | | **State of Charge**| | + | |
- | | 100| 12.70| | + | |
- | | 90| 12.60| | + | |
- | | 80| 12.40| | + | |
- | | 70| 12.30| | + | |
- | | 60| 12.20| | + | |
- | | 50| 12.10| | + | |
- | | 40| 12.00| | + | |
- | | 30| 11.80| | + | |
- | | 20| 11.65| | + | |