User Tools

Site Tools


electrical:12v:self-jumpstarting

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
electrical:12v:self-jumpstarting [2021/06/25 13:12]
frater_secessus [voltage sensing relays]
electrical:12v:self-jumpstarting [2021/06/25 13:20]
frater_secessus [voltage sensing relays]
Line 22: Line 22:
  
 Examples:   Examples:  
 +
 +  * [[https://amzn.to/2Ri2jQV|Battery Doctor]] - integrated button
 +  * [[http://amzn.to/2h2tDxp|Sure Power 1314]] - user-added wiring(("Connect a #14 gauge wire from the start position of the ignition switch to the Start terminal of the Battery Separator. Make this connection at the ignition switch. This wire should only have voltage when the ignition switch is in the start position. Note: The start signal must be able to produce at least 3V* in order to provide automatic boost, see connection diagram above for manual operation option." - https://www.ase-supply.com/Sure_Power_1314_200_Battery_Separator_p/sp-1314-200.htm))
 +  * [[https://amzn.to/3h5iMUd|Victron CT]] - user-added wiring to "start assist" terminal
  
 ==== relays ==== ==== relays ====
electrical/12v/self-jumpstarting.txt ยท Last modified: 2024/03/22 08:19 by frater_secessus