User Tools

Site Tools


electrical:converter

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
electrical:converter [2019/03/12 18:02]
frater_secessus [DIY converters]
electrical:converter [2020/07/22 14:52]
frater_secessus [DIY smart converters]
Line 23: Line 23:
 ===== aftermarket converters ===== ===== aftermarket converters =====
  
-Aftermarket converters tend to be higher quality than OEM, but some are still "dumb" single-stage chargers.  Higher-end aftermarket converters often have multistage charging built in, or available as an upgrade.((See the PD w/Charge Wizard below))+Aftermarket converters tend to be higher quality than OEM, but some are still "dumb" single-stage chargers.  Higher-end aftermarket converters often have multistage charging built in, or available as an upgrade.((See the PD w/Charge Wizard below))  Note that a "dumb" charger might be fine if you have solar power on the vehicle, as the [[electrical:solar:charge_controller|solar charge controller]] is likely a "smart" charger. 
  
 Three converter makers are generally respected on the CRVL forum.  In alphabetical order: Three converter makers are generally respected on the CRVL forum.  In alphabetical order:
Line 40: Line 41:
 ==== DIY dumb converters ==== ==== DIY dumb converters ====
  
-Dumb converters output a single voltage (see above).  +"Dumbconverters output a single voltage and work fine when solar charging is present (see above).  In this scenario the 12v power supply can is set to ~13.x voltages to provide "float" support while on shore power.  
  
-FIXME+If loads are run off the converter in the daytime the converter will just be supporting the solar yield and can be rather small.  If used at night the converter will be carrying the whole burdern should be sized to your expected loads ([[https://amzn.to/2WNSIDL|20A]], [[https://amzn.to/3jwQGBO|40A]], whatever).
  
  
Line 54: Line 55:
   * secondary use of charge controller as a spare if needed   * secondary use of charge controller as a spare if needed
  
-If you do not need smart charging an adjustable voltage power supply could do the trick.  Since by definition the batteries aren't cycling when on shore power you could adjust it to something like 13.2v and let it "float" charge over time. +
electrical/converter.txt · Last modified: 2024/02/28 15:19 by frater_secessus