This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
electrical:generator [2023/09/23 13:20] frater_secessus [inverter generators] |
electrical:generator [2023/09/23 13:32] frater_secessus [inverter generators] |
||
---|---|---|---|
Line 15: | Line 15: | ||
===== inverter generators ===== | ===== inverter generators ===== | ||
- | Standard | + | To understand the theoretical benefits of inverter |
- | [[https:// | + | **Standard generators** run the engine at a specific speed to get a stable 60Hz((in the U.S.)) output frequency. |
+ | |||
+ | > Typically, a United States portable generator runs at 3600 RPM, with 2 poles, for a design frequency of 60Hz.((https:// | ||
+ | |||
+ | Things that affect RPM (load changes, etc) will affect the output and can cause "dirty power" (varying frequency). | ||
+ | |||
+ | > You get fluctuation of frequency and voltage as the load changes because the engine cannot respond immediately to the actual load change. There are regulators controlling the engine throttle that attempt to keep the engine at a fixed (design) speed, but it takes time for the engine to respond to new commands as it has to deal with varying fuel/air mixtures and combustion which aren't instantaneous.((https:// | ||
+ | |||
+ | |||
+ | [[https:// | ||
**Notes**: | **Notes**: | ||
Line 89: | Line 98: | ||
===== cooling ===== | ===== cooling ===== | ||
- | Most portable generators used by ' | + | Most portable generators used by ' |
The generator should be placed in shade((like under a tree)) when possible to keep it from heating up further from direct sun. | The generator should be placed in shade((like under a tree)) when possible to keep it from heating up further from direct sun. |