This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
electrical:solar:charge_controller [2018/06/30 19:38] frater_secessus [Using LOAD output] |
electrical:solar:charge_controller [2018/11/20 13:06] frater_secessus |
||
---|---|---|---|
Line 49: | Line 49: | ||
* during times of low irradience (low light levels due to low angle or overcast conditions)((this is a function of higher input voltages))((https:// | * during times of low irradience (low light levels due to low angle or overcast conditions)((this is a function of higher input voltages))((https:// | ||
- | === designing for MPPT === | + | There are some considerations when [[electrical: |
- | + | ||
- | There are benefits from using [[electrical: | + | |
- | + | ||
- | MPPT controllers are most efficient when input voltage (Vpanel) is about 2x nominal battery voltage (Vbatt). | + | |
==== shunt ==== | ==== shunt ==== | ||
Line 109: | Line 105: | ||
===== multiple charge controllers | ===== multiple charge controllers | ||
- | Multiple controllers (with separate arrays) can be used to charge a common bank. The controllers should be configured with similar charging setpoints for the greatest efficiency.((http:// | + | [[electrical: |
Line 128: | Line 124: | ||
===== Using LOAD output ===== | ===== Using LOAD output ===== | ||
- | It is common for charge controllers to have a LOAD output for powering (or switching) loads. | + | It is common for charge controllers to have a LOAD output for powering (or switching) loads. |
+ | |||
+ | Not all types of loads should be run from these terminals, though. | ||
> Heavily inductive or capacitive loads such as **pumps, motors, compressors, | > Heavily inductive or capacitive loads such as **pumps, motors, compressors, | ||
Line 135: | Line 133: | ||
elsewhere they say: | elsewhere they say: | ||
- | > Inductive loads can generate large voltage spikes that may damage the controller’s lightning protection | + | > Inductive loads can generate large voltage spikes that may damage the controller’s lightning protection devices.((http:// |
- | devices.((http:// | + | |
although an exception is made for the SunSaver MPPT which " | although an exception is made for the SunSaver MPPT which " |