Line 18: Line 18:
   * **Minimum charge rate:**  not stated in our example, but typical minimum charging values are ~C/10 for lead chemistries.    * **Minimum charge rate:**  not stated in our example, but typical minimum charging values are ~C/10 for lead chemistries. 
   * **Temperature compensation** - how the voltage setpoints are adjusted for temperature.  While this is sometimes configurable, generally the compensation factor is close enough between manufacturers that it can be left at the default.    * **Temperature compensation** - how the voltage setpoints are adjusted for temperature.  While this is sometimes configurable, generally the compensation factor is close enough between manufacturers that it can be left at the default. 
-  * **Absorption termination** - the amount of current (or percentage of capacity) Absorption falls to before completion.  This is used to decide when the controller should go to Float It's not given in this chart, but elsewhere +  * **Absorption termination** - the amount of current (or percentage of capacity) accepted by the battery in late Absorption that indicates it's appropriate to Float.  In the lower-right of [[https://www.trojanbattery.com/pdf/Trojan_QSG_AGM.pdf|this graph]] Trojan shows it as [[electrical:12v:battery_capacity|C]]/200: 
 + 
 +{{ :electrical:solar:endamps.png?400 |}}
  
  