===== timing opportunity loads ===== | ===== timing opportunity loads ===== | ||
+ | |||
+ | The trickiest part of running opportunity loads is running them at the right time so battery charging is not affected. | ||
+ | |||
+ | |||
+ | ==== manual model ==== | ||
+ | |||
+ | |||
You can start the loads **manually** (ie, start using the power when you have extra). | You can start the loads **manually** (ie, start using the power when you have extra). | ||
Line 65: | Line 72: | ||
In this approach the LVD is set just below Vfloat as above, but activation of the loads is delayed by some amount of time. Observation of the system during charging will suggest how long it normally takes takes charging amperage to drop off (ie, when the system has surplus current). | In this approach the LVD is set just below Vfloat as above, but activation of the loads is delayed by some amount of time. Observation of the system during charging will suggest how long it normally takes takes charging amperage to drop off (ie, when the system has surplus current). | ||
- | Suggested delay for conservative opportunity loading == the time from [passing Vlvr setpoint during Bulk] to [completed charging].((settling to Float)). | + | Suggested delay for conservative opportunity loading == the time from [passing Vlvr setpoint during Bulk] to [completed charging].((settling to Float)). |
Line 76: | Line 83: | ||
==== LVD + timer - eternal Absorption ==== | ==== LVD + timer - eternal Absorption ==== | ||
- | This setup avoids timer juggling/ | + | This setup avoids timer juggling/ |
- [[electrical: | - [[electrical: | ||
Line 82: | Line 89: | ||
- set the LVD to just under Vabs, set the timer to the Absorption duration | - set the LVD to just under Vabs, set the timer to the Absorption duration | ||
+ | Similar to the above, this setup looks like: [LVD or controller LOAD output] โ> timer โ> relay โ> load | ||