This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
electrical:solar:overpaneling [2018/07/20 16:23] frater_secessus [how MPPT controllers clip power] |
electrical:solar:overpaneling [2019/02/11 12:08] frater_secessus [Overpaneling] |
||
---|---|---|---|
Line 3: | Line 3: | ||
**Overpaneling** has two related meanings; | **Overpaneling** has two related meanings; | ||
- | * [[# | + | * [[# |
- | * [[# | + | * [[# |
Line 30: | Line 30: | ||
* you want to get deeply cycled batteries charging as early as possible in the morning | * you want to get deeply cycled batteries charging as early as possible in the morning | ||
* you spend most of your time in areas with [[electrical: | * you spend most of your time in areas with [[electrical: | ||
+ | * you spend time in partial shade | ||
* you want to use a smaller controller instead of jumping up to the next size. Example, 43A max output and your choices are 40A or 60A controllers. | * you want to use a smaller controller instead of jumping up to the next size. Example, 43A max output and your choices are 40A or 60A controllers. | ||
Line 39: | Line 40: | ||
- when there is very little load being used | - when there is very little load being used | ||
- | This occurs because the PPT controller moves Vpanel toward Voc to reduce current when less is needed but battery voltage is high, as in late Absorption . | + | This occurs because the PPT controller moves Vpanel toward Voc to reduce current when less is needed but battery voltage is high, as in late Absorption. |
Line 82: | Line 83: | ||
The heavy vertical black line((also added by secessus)) comes down from that intersection at 21v.((It also crosses at ~11v but most MPPT downconvert rather than boost, so 11v is not useful.)) | The heavy vertical black line((also added by secessus)) comes down from that intersection at 21v.((It also crosses at ~11v but most MPPT downconvert rather than boost, so 11v is not useful.)) | ||
- | In this case the controller wants to limit panel output to 65w So it runs the panel at 21v, which is a far cry from Vmp. Then it downconverts the excess voltage to amps: it charges the battery((or runs loads)) 5A @ 13v.((this | + | In this case the controller wants to limit panel output to 65w So it runs the panel at 21v, which is a far cry from Vmp. Then it downconverts the excess voltage to amps: it charges the battery((or runs loads)) 5A @ 13v. |
=== corollaries === | === corollaries === | ||
If you have the curve and Vpanel you can derive the power output. \\ | If you have the curve and Vpanel you can derive the power output. \\ | ||
If you have the curve and you know Wpanel you can derive Vpanel. \\ | If you have the curve and you know Wpanel you can derive Vpanel. \\ | ||
- | If you have a lot of time and patience, you can plot Vpanel and Wpanel to draw the curve yourself. | + | If you have a lot of time and patience, you can plot Vpanel and Wpanel to draw the curve yourself. |
- | + | An MPPT controller is //always// **T**racking and using powerpoints, | |
===== vs. battery bank ===== | ===== vs. battery bank ===== | ||