User Tools

Site Tools


electrical:solar:panel-bank_ratio

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision Both sides next revision
electrical:solar:panel-bank_ratio [2017/10/01 10:46]
frater_secessus created
electrical:solar:panel-bank_ratio [2017/10/01 10:49]
frater_secessus
Line 3: Line 3:
 A common rule of thumb for sizing batteries to solar power relates nominal panel output in Watts to bank capacity in Ah.   A common rule of thumb for sizing batteries to solar power relates nominal panel output in Watts to bank capacity in Ah.  
  
-//1:1// == 200W((nominal)) solar + 200Ah battery bank.  \\ +//1:1// == 200W solar + 200Ah battery bank.  \\ 
  
-//2:1// == 200W((nominal)) solar + 100Ah of battery. ([[electrical:solar:overpaneling|overpaneling]])+//2:1// == 200W solar + 100Ah of battery. ([[electrical:solar:overpaneling|overpaneling]])
  
-//1:2// would mean 100W((nominal)) solar + 200Ah of battery. (underpaneling or [[electrical:solar:overbanking|overbanking]])+//1:2// == 100W solar + 200Ah of battery. (underpaneling or [[electrical:solar:overbanking|overbanking]]) 
 + 
 +For solar-only charging 2:1 or even 3:1 is recommmended. 
 +For [[electrical:shore_power|shorepower-]] or [[electrical:12v:alt_and_solar|alternator-]]augmented charging 1:1 or 1:2 may be sufficient.
  
  
  
electrical/solar/panel-bank_ratio.txt · Last modified: 2023/10/22 10:45 by frater_secessus