electrical:solar:panels [2018/05/19 08:05]
frater_secessus [panel voltage] 48 fix
electrical:solar:panels [2018/05/19 08:11]
frater_secessus [monocrystalline]
Line 23: Line 23:
     * slightly better than poly in uniform low light     * slightly better than poly in uniform low light
     * theoretically greater longevity than poly, much better longevity than thin film     * theoretically greater longevity than poly, much better longevity than thin film
-    * slightly higher Vmpp than poly((https://www.victronenergy.com/upload/documents/White-paper-Which-solar-charge-controller-PWM-or-MPPT.pdf Section 7.4)) +    * slightly higher [[electrical:12v:electrical_notation|Vmp]] than poly((https://www.victronenergy.com/upload/documents/White-paper-Which-solar-charge-controller-PWM-or-MPPT.pdf Section 7.4)) 
-    * slightly better performance in higher temps than poly, possibly due to higher Vmpp+    * slightly better performance in higher temps than poly, possibly due to higher Vmp
   * CON   * CON
     * most expensive to produce     * most expensive to produce
electrical/solar/panels.txt · Last modified: 2024/05/28 22:01 by frater_secessus