electrical:solar:series_vs_parallel [2020/05/04 10:31]
frater_secessus [Series]
electrical:solar:series_vs_parallel [2020/05/04 10:32]
frater_secessus [Series]
Line 11: Line 11:
     * higher PV voltage can run in relatively **thinner wires** to the charge controller     * higher PV voltage can run in relatively **thinner wires** to the charge controller
     * serial connections can provide **some charging in low light situations** where lower voltage parallel or single-panel connections might not.  Imagine two nominal 12v panels running at 11v at sunrise;   the series arrangement might yield ~22v (battery charging) instead of 11v (voltage too low to charge battery).  Note that power harvestable at those times may be quite low.      * serial connections can provide **some charging in low light situations** where lower voltage parallel or single-panel connections might not.  Imagine two nominal 12v panels running at 11v at sunrise;   the series arrangement might yield ~22v (battery charging) instead of 11v (voltage too low to charge battery).  Note that power harvestable at those times may be quite low. 
-   * higher-voltage serial configurations with MPPT controllers may provide [[electrical:solar:shading#exceptionhigh_voltage_strings_mppt|more power under partial shading]] +    * higher-voltage serial configurations with MPPT controllers may provide [[electrical:solar:shading#exceptionhigh_voltage_strings_mppt|more power under partial shading]] 
     * higher voltages **work well with MPPT controllers**     * higher voltages **work well with MPPT controllers**
     * higher voltages can **charge higher voltage battery systems** like 24v.     * higher voltages can **charge higher voltage battery systems** like 24v.
Line 20: Line 20:
     * **requires MPPT charger** to get full use of high-voltage arrays under normal conditions.     * **requires MPPT charger** to get full use of high-voltage arrays under normal conditions.
     * thin film panels are generally not recommended for use in serial arrays     * thin film panels are generally not recommended for use in serial arrays
-    * **more susceptible to partial shading** problems than parallel+    * short serial strings are **more susceptible to partial shading** losses than parallel
  
  
electrical/solar/series_vs_parallel.txt ยท Last modified: 2024/03/09 11:00 by frater_secessus