 ==== how it works ==== ==== how it works ====
  
-  - a simple [[electrical:solar:charge_controller#shunt_controller|shunt charge controller]] holds the battery at a mild Absorption voltage (14.0, - 14.2v) when charging, just below the gassing point+  - a simple [[electrical:solar:charge_controller#shunt_controller|shunt charge controller]] holds the battery at a mild Absorption voltage (14.0, - 14.2v) when charging, just below the significant gassing point
   - the controller's LOAD output disconnects (LVD) at 100% SoC (~12.7v)   - the controller's LOAD output disconnects (LVD) at 100% SoC (~12.7v)
   - the controller's LOAD output //re//connects (LVR) at ~13.0v);  see discussion below   - the controller's LOAD output //re//connects (LVR) at ~13.0v);  see discussion below
Line 27: Line 27:
 If **running larger loads** (fans, laptop chargers) the setpoint should be set higher (like 13.5v - 14.0v).  This is because the panel will be able to make more power closer to Vmp.  Consider the popular [[http://amzn.to/2you3Kj|Renogy 100w panel]] that puts out about 5.29A.  At the lower LVR the panel((under lab conditions)) will make **68.77W**.  At the higher LVRs the panel will make **71.42-74.06W** If **running larger loads** (fans, laptop chargers) the setpoint should be set higher (like 13.5v - 14.0v).  This is because the panel will be able to make more power closer to Vmp.  Consider the popular [[http://amzn.to/2you3Kj|Renogy 100w panel]] that puts out about 5.29A.  At the lower LVR the panel((under lab conditions)) will make **68.77W**.  At the higher LVRs the panel will make **71.42-74.06W**
  
-Note:  running a small MPPT [[electrical:solar:charge_controller|charge controller]] would make this immaterial, as the controller would run the panel at max power (Vmp) at 18.9v.+Note:  running a small [[electrical:solar:charge_controller#mppt|MPPT]] [[electrical:solar:charge_controller|charge controller]] would make this immaterial, as the controller would run the panel at max power (Vmp) at 18.9v.
  
  