electrical:solar:shallow_cycling [2018/03/02 09:44] frater_secessus [how it works] relay |
electrical:solar:shallow_cycling [2018/03/02 09:47] frater_secessus [how it works] |
==== how it works ==== | ==== how it works ==== |
| |
- a simple [[electrical:solar:charge_controller#shunt_controller|shunt charge controller]] holds the battery at a mild Absorption voltage (14.0, - 14.2v) when charging, just below the gassing point | - a simple [[electrical:solar:charge_controller#shunt_controller|shunt charge controller]] holds the battery at a mild Absorption voltage (14.0, - 14.2v) when charging, just below the significant gassing point |
- the controller's LOAD output disconnects (LVD) at 100% SoC (~12.7v) | - the controller's LOAD output disconnects (LVD) at 100% SoC (~12.7v) |
- the controller's LOAD output //re//connects (LVR) at ~13.0v); see discussion below | - the controller's LOAD output //re//connects (LVR) at ~13.0v); see discussion below |
If **running larger loads** (fans, laptop chargers) the setpoint should be set higher (like 13.5v - 14.0v). This is because the panel will be able to make more power closer to Vmp. Consider the popular [[http://amzn.to/2you3Kj|Renogy 100w panel]] that puts out about 5.29A. At the lower LVR the panel((under lab conditions)) will make **68.77W**. At the higher LVRs the panel will make **71.42-74.06W** | If **running larger loads** (fans, laptop chargers) the setpoint should be set higher (like 13.5v - 14.0v). This is because the panel will be able to make more power closer to Vmp. Consider the popular [[http://amzn.to/2you3Kj|Renogy 100w panel]] that puts out about 5.29A. At the lower LVR the panel((under lab conditions)) will make **68.77W**. At the higher LVRs the panel will make **71.42-74.06W** |
| |
Note: running a small MPPT [[electrical:solar:charge_controller|charge controller]] would make this immaterial, as the controller would run the panel at max power (Vmp) at 18.9v. | Note: running a small [[electrical:solar:charge_controller#mppt|MPPT]] [[electrical:solar:charge_controller|charge controller]] would make this immaterial, as the controller would run the panel at max power (Vmp) at 18.9v. |
| |
| |