 ==== transitioning to float ==== ==== transitioning to float ====
  
-When transitioning from Absorption to Float the voltage needs to drop about a volt.  The system will "free-fall" (make little or no power) to allow the voltage to fall.  The transition may take seconds or minutes, depending on how/if the system is loaded.+When transitioning from Absorption to Float the voltage needs to drop about a volt.  The system will "free-fall" (make little or no power) to allow the voltage to fall.((with MPPT controllers you may see Vpanel go quite close to Voc))   The transition may take seconds or minutes, depending on how/if the system is loaded.
  
-  * starts at Vabs +  * Vbatt starts at Vabs 
-  * power generation stops +  * power harvest is cut off or greatly curtailed 
-  * voltage drops to Vfloat +  * vbatt drops to Vfloat  
-  * when voltage reaches Vfloat the system will start making power to hold that setpoint.+  * when voltage reaches Vfloat the system will start making power to hold //that// setpoint.
  
  