electrical:solar:status [2022/08/09 12:11]
frater_secessus [in absorption]
electrical:solar:status [2023/07/13 18:44]
frater_secessus [sudden voltage spikes]
Line 81: Line 81:
  
  
-**During [[electrical:12v:charging#absorption#absorption_stage|Absorption]] charging** lead-acid batteries will need less and less current.+**During [[electrical:12v:charging#absorption#absorption_stage|Absorption]] charging** batteries will need less and less current.
  
 **with MPPT controllers** **with MPPT controllers**
Line 182: Line 182:
  
  
 +===== sudden voltage spikes =====
  
 +If you are seeing sudden voltage spikes and have lithium batteries, you may be seeing [[opinion:frater_secessus:lifepo4_charging_voltage|the BMS disconnect charging]].
  
 +===== MPPT tracking sweeps =====
  
  
 +An **MPPT** controller sweeps the **P**ower **P**oints along the array voltage curve in order to **T**rack the **M**aximum (and non-maxiumum) power points.  
 +
 +Depending on the algorithm the sweep may be local to the present Vpanel, or may be a sweep from 0v-Voc, or anything in between.  It may happen often or seldem.  
 +
 +The sweep will interfere with power production so the mfg attempts to find a balance between
 +
 +  * constant production, and
 +  * learning whether or not one is operating at the ideal power poing
  
  
electrical/solar/status.txt ยท Last modified: 2024/01/14 15:32 by frater_secessus