User Tools

Site Tools


opinion:frater_secessus:solar_not_charging

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
opinion:frater_secessus:solar_not_charging [2023/09/04 18:58]
frater_secessus [further reading]
opinion:frater_secessus:solar_not_charging [2023/09/04 20:24]
frater_secessus [because no power is being demanded]
Line 1: Line 1:
 ====== My solar isn't charging ====== ====== My solar isn't charging ======
  
-Reminder:  a [[electrical:solar:charge_controller|solar charge controller]] +Reminder:  a [[electrical:solar:charge_controller|solar charge controller]] makes power
  
-  - makes power 
-  - up to its abilities under present conditions 
   - //when power is demanded// for [[electrical:12v:charging|charging]] or [[electrical:12v:loads|loads]]   - //when power is demanded// for [[electrical:12v:charging|charging]] or [[electrical:12v:loads|loads]]
 +  - up to its abilities under present conditions
  
- +In most cases the system is working as designed but the owner doesn't know it.  
-So why does it not make power sometimes?+
  
  
Line 19: Line 17:
  
  
 +==== charge-and-stop ====
  
 +Charge-and-stop usually charges to 14.2v or 14.4v then stops until nank voltage drops to 13.2v before restarting Bulk charging. 
 +
 +Under very light loads this would result in cycling between 90% and 100% state of charge.  Because of [[electrical:12v:voltage_sag|voltage sag]] heavy loads might result in cycling between 95% - 100%.  
 +
 +If this is undesirable behavior you can set up a USER profile with whatever setpoints you wish ([[electrical:12v:drop-in_lifepo4#mythyou_can_t_charge_li_with_a_lead_battery_charger|suggested settings]]).
 ===== because the panels aren't receiving full sunlight ===== ===== because the panels aren't receiving full sunlight =====
  
Line 25: Line 29:
   * rainclouds   * rainclouds
   * inside a parking garage or under a tree, etc   * inside a parking garage or under a tree, etc
 +
 +
 +===== because the BMS has shut down charging =====
 +
 +...because of temperature extremes of [[opinion:frater_secessus:lifepo4_charging_voltage|excessive charging voltage]]. (lithium only)
 +
  
 ===== because something has actually gone wrong ===== ===== because something has actually gone wrong =====
Line 33: Line 43:
  
 ====== further reading ====== ====== further reading ======
-   + 
-   + 
-[[electrical:solar:status|is my solar working]]+  [[electrical:solar:status|is my solar working?]] 
  
opinion/frater_secessus/solar_not_charging.txt · Last modified: 2023/09/04 20:26 by frater_secessus