| Both sides previous revision
Previous revision
Next revision
|
Previous revision
|
electrical:12v:drop-in_lifepo4 [2025/04/19 16:50] frater_secessus [myth: you have to charge Li to 100%] reset link |
electrical:12v:drop-in_lifepo4 [2025/11/22 00:16] (current) frater_secessus [BMS features and specs] |
| ===== drawbacks of lithium ===== | ===== drawbacks of lithium ===== |
| |
| * Li is relatively expensive up front | * Li has (historically at least) been relatively expensive up front. Prices started plummeting somewhere around 2024. |
| * Li cells need a [[#bms_functions|BMS]] to protect them from damage.((some DIYers run Li "barefoot" (without a BMS) )) For example, Li can be damaged by overvoltage, undervoltage, charging below freezing (32F), etc. Some batteries have low-temp cutoff and/or internal heating to address the cold-charging limitation. Most Drop-in Lithium batteries will have a BMS integrated into them, but raw cells do not. | * Li cells need a [[#bms_functions|BMS]] to protect them from damage.((some DIYers run Li "barefoot" (without a BMS) )) For example, Li can be damaged by overvoltage, undervoltage, charging below freezing (32F), etc. Some batteries have low-temp cutoff and/or internal heating to address the cold-charging limitation. Most Drop-in Lithium batteries will have a BMS integrated into them, but raw cells do not. |
| * Li can be **damaged** by long duration at full charge or high voltage, or high ambient temperatures | * Li can be **damaged** by long duration at full charge or high voltage, or high ambient temperatures |
| ===== choosing a drop-in LFP battery ===== | ===== choosing a drop-in LFP battery ===== |
| |
| There are many factors here which only you will be able to assess. | There are many factors here which only you will be able to assess. Basic due diligence will involve: |
| | |
| | * reading and understanding the specs (see below) |
| | * searching for youtube teardowns and testing on that particular model |
| | |
| | Shortcut: Will Prowse has [[https://www.mobile-solarpower.com/lithium-batteries.html|a list of recommended, tested batteries]] which can be trusted. |
| | |
| | **Heads up**: do not use lowest-possible-price as the main criterion for a battery unless there was a test/teardown available for it. |
| |
| ==== voltage ==== | ==== voltage ==== |
| |
| LFP cells can be damaged by overvoltage. Charging is typically disabled when one or more cells rises to ~3.65v (~14.6vv for the pack) | LFP cells can be damaged by overvoltage. Charging is typically disabled when one or more cells rises to ~3.65v (~14.6vv for the pack) |
| | |
| | |
| | === low temperature (~freezing) charge cutoff === |
| | |
| | [not present in all BMS] |
| | |
| | LFP cells are damaged by charging when the cells are at ~freezing temperatures.((discharging too, but the limits are much colder)) |
| | |
| | Lack of **low temperature cutoff** is not necessarily a deal-breaker. Maybe you live in a hot location. Maybe your chargers have low temperature cutoff. Maybe you externally warm your battery. |
| | |
| | [[opinion:frater_secessus:self-heated_lifepo4|externally warmed vs. self-heated LiFePO4]] |
| | |
| | |
| |
| === high temperature charge/discharge cutoff === | === high temperature charge/discharge cutoff === |
| |
| |
| === low temperature (~freezing) charge cutoff === | |
| |
| [not present in all BMS] | |
| |
| LFP cells are damaged by charging when the cells are at ~freezing temperatures.((discharging too, but the limits are much colder)) | |
| |
| Lack of **low temperature cutoff** is not necessarily a deal-breaker. Maybe you live in a hot location. Maybe your chargers have low temperature cutoff. Maybe you externally warm your battery. | |
| |
| [[opinion:frater_secessus:self-heated_lifepo4|externally warmed vs. self-heated LiFePO4]] | |
| |
| |
| |
| |
| Capacitive balancing wastes less power since most of the excess is transferred to the low cell[s]. There are efficiency losses involved (~50%((https://www.ti.com/download/trng/docs/seminar/Topic%202%20-%20Battery%20Cell%20Balancing%20-%20What%20to%20Balance%20and%20How.pdf))) but it's far less than the 100% loss of passive balancing. The main drawbak of capacitive balancers is the current spec (like 5A) only occur at huge deltas; the rest of the time the balancing current is much lower. | **Capacitive balancing** wastes less power since most of the excess is transferred to the low cell[s]. There are efficiency losses involved (~50%((https://www.ti.com/download/trng/docs/seminar/Topic%202%20-%20Battery%20Cell%20Balancing%20-%20What%20to%20Balance%20and%20How.pdf))) but it's far less than the 100% loss of passive balancing. The main drawbak of capacitive balancers is the current spec (like 5A) only occur at huge deltas; the rest of the time the balancing current is much lower. |
| | |
| | Heads up: because active balancers are just shuffling voltage between cells they can overdischarge the cells if left alone without adult supervision. To avoid this: |
| | |
| | * use [[electrical:12v:lvd|an LVD]] to cut the circuit to the balancer's single NEG lead when pack voltage is <13.0v or some other value of your choosing. Or, |
| | * choose an active balancer that has a built-in LVD.((The cutoff tends to be something like 3.0Vpc, so 12.0v for a 4S 12v pack.)) Or, |
| | * only run the active balancer manually when required |
| |
| In theory inductive active balancers would get around this delta/current relationship. [as of this writing in 2024 I know of no drop-ins that use inductive active balancers - secessus] | In theory **inductive active balancers** would get around this delta/current relationship. [as of this writing in 2024 I know of no drop-ins that use inductive active balancers - secessus] |
| |
| |
| |
| Further reading: [[https://www.youtube.com/results?search_query=offgrid+garage+absorption|Off-grid Garage videos]] testing various absorption approaches | Further reading: [[https://www.youtube.com/results?search_query=offgrid+garage+absorption|Off-grid Garage videos]] testing various absorption approaches |
| | |
| | ==== myth: you shouldn't Float lithium ==== |
| | |
| | Li certainly doesn't need Float voltage (Vfloat) in the sense lead-chemistry batteries do, but the Float setpoint is still useful for Li battery banks.((Li batts with active balancers or other parasitic loads may be drawn down by them)) |
| | |
| | Reminder: lead requires Float because |
| | |
| | - lead banks need to be held at 100% SoC whenever possible for their long-term health |
| | - the self-discharge rate is so high that they lose capacity just sitting there |
| | |
| | Neither of these is true for Li, which dislikes sitting at 100% SoC and has vanishingly-low self-discharge rates.((but see [[https://www.technomadia.com/2020/06/what-killed-our-rv-lithium-batteries-8-5-years-of-lifepo4/|this cautionary tale]] about add-on balancers depleting/killing a $4,000 bank)) So **with lithium Float is used for a different purpose**, as a **voltage floor**. It is a voltage below which the charger shouldn't let the bank fall while charging is present. Without Vfloat (or a very low one) the bank would charge then fall until reaching the "re-bulk" setpoint.((when a fresh charge cycle begins)). After initial charging loads would run off the battery instead of the charging source. Having a sane Vfloat allows Li to "relax" after charging while retaining the desired amount of Ah/Wh capacity. |
| | |
| | What Vfloat setpoint should actually be is a matter of some discussion and experimentation. Each setup (and use case) is different, but we can start with some ballpark assumptions:((and using nominal 12v math)) |
| | |
| | |
| | * <13.4v will allow the bank to settle below 100% |
| | * ~13.4v will hold the bank near whatever SoC it was charged to. If in doubt, this is a good default for solar charging.((When charging from shore power 13.4v will eventually charge and hold at 100% SoC, which may be undesirable)) |
| | * >13.4v will continue to charge the bank beyond the SoC it was charged to during Absorption. This may be useful if the Vabs value is set intentionally low. |
| | |
| | |
| | If you cannot set a Float within the confines of the Li profile then leverage the USER or GEL profile, modifying as described in the previous section. |
| | |
| | ==== myth: you can't equalize LFP ==== |
| | |
| | LFP does not require [[electrical:12v:charging#equalization|Equalization]] (controlled overcharge) the way lead does.((in a sense [[opinion:frater_secessus:lifepo4_charging_voltage|charging LFP at higher-than-necessary voltages]] is akin to EQ)). |
| | |
| | Having said that, folks who regularly charge to less than 100% SoC might use the EQ setpoint to schedule occasional forays to 100% in order to [[electrical:12v:battery_monitor#drift_and_reset|reset the Ah counters]]. A user who regularly charges to 13.5v might use EQ to drive the bank to 14.4v every few weeks. |
| ==== myth: you can't charge Li with a lead battery charger ==== | ==== myth: you can't charge Li with a lead battery charger ==== |
| |
| Depends on the charger and how your Li wants to be charged. Most **fully-configurable** chargers can be used to charge Li.((Some simpler controllers that only have selectable presets like AGM or gel //may// have a preset that overlaps with the correct charging specs for your battery. Read the specs carefully.)) Note that some so-called "lithium compatible" chargers may have presets that do not match the requirements of your particular battery, so read the specs. | Depends on the charger and how your Li wants to be charged. Most **fully-configurable** chargers can be used to charge Li.((Some simpler controllers that only have selectable presets like AGM or gel //may// have a preset that overlaps with the correct charging specs for your battery. Read the specs carefully.)) Note that some so-called "lithium compatible" chargers may have presets that do not match the requirements of your particular battery, so read the specs. |
| | |
| | This info can also be used to make a custom (USER) profile for LiFePO4 banks. |
| |
| Here is the order of operations: | Here is the order of operations: |
| Note: if you are willing to pay minimal attention, even a single-voltage power supply or [[electrical:12v:alternator#combiners|relay]] would work. Stop charging if/when the voltage hits your desired setpoint. | Note: if you are willing to pay minimal attention, even a single-voltage power supply or [[electrical:12v:alternator#combiners|relay]] would work. Stop charging if/when the voltage hits your desired setpoint. |
| |
| ==== myth: you shouldn't Float lithium ==== | |
| |
| Li certainly doesn't need Float voltage (Vfloat) in the sense lead-chemistry batteries do, but the Float setpoint is still useful for Li battery banks.((Li batts with active balancers or other parasitic loads may be drawn down by them)) | |
| |
| Reminder: lead requires Float because | |
| |
| - lead banks need to be held at 100% SoC whenever possible for their long-term health | |
| - the self-discharge rate is so high that they lose capacity just sitting there | |
| |
| Neither of these is true for Li, which dislikes sitting at 100% SoC and has vanishingly-low self-discharge rates.((but see [[https://www.technomadia.com/2020/06/what-killed-our-rv-lithium-batteries-8-5-years-of-lifepo4/|this cautionary tale]] about add-on balancers depleting/killing a $4,000 bank)) So **with lithium Float is used for a different purpose**, as a **voltage floor**. It is a voltage below which the charger shouldn't let the bank fall while charging is present. Without Vfloat (or a very low one) the bank would charge then fall until reaching the "re-bulk" setpoint.((when a fresh charge cycle begins)). After initial charging loads would run off the battery instead of the charging source. Having a sane Vfloat allows Li to "relax" after charging while retaining the desired amount of Ah/Wh capacity. | |
| |
| What Vfloat setpoint should actually be is a matter of some discussion and experimentation. Each setup (and use case) is different, but we can start with some ballpark assumptions:((and using nominal 12v math)) | |
| |
| |
| * <13.4v will allow the bank to settle below 100% | |
| * ~13.4v will hold the bank near whatever SoC it was charged to. If in doubt, this is a good default for solar charging.((When charging from shore power 13.4v will eventually charge and hold at 100% SoC, which may be undesirable)) | |
| * >13.4v will continue to charge the bank beyond the SoC it was charged to during Absorption. This may be useful if the Vabs value is set intentionally low. | |
| |
| |
| If you cannot set a Float within the confines of the Li profile then leverage the USER or GEL profile, modifying as described in the previous section. | |
| ==== myth: you must use DC-DC for alternator charging Li ==== | ==== myth: you must use DC-DC for alternator charging Li ==== |
| |