* **Maximum input voltage** - the highest voltage the controller should //ever// see from the solar array.((it is common to leave ~20% margin)) NOTE: a 50v input max does //not// mean a PWM controller can make efficient use of mismatched panel/battery voltages; that requires MPPT. See [[#how_to_choose|how to choose]] below. | * **Maximum input voltage** - the highest voltage the controller should //ever// see from the solar array.((it is common to leave ~20% margin)) NOTE: a 50v input max does //not// mean a PWM controller can make efficient use of mismatched panel/battery voltages; that requires MPPT. See [[#how_to_choose|how to choose]] below. |
* **Minimum input voltage** - a PWM controller will requires panel voltage ≥ battery voltage to charge. MPPT controllers will usually require a bit more voltage headroom to start/run the MPPT algorithm.((although less common, //boosting// MPPT do exist that can increase incoming voltage in order to charge a higher-voltage battery bank)) | * **Minimum input voltage** - a PWM controller will requires panel voltage ≥ battery voltage to charge. MPPT controllers will usually require a bit more voltage headroom to start/run the MPPT algorithm.((although less common, //boosting// MPPT do exist that can increase incoming voltage in order to charge a higher-voltage battery bank)) |
* **Maximum input current** is uncommon in standalone controllers but common in [[12v:sg_troubleshooting#must_i_use_the_ps_brand_s_proprietary_solar_panels|the controllers built into "power stations"]]. | * **Maximum input current** is uncommon in standalone MPPT controllers but common in [[12v:sg_troubleshooting#must_i_use_the_ps_brand_s_proprietary_solar_panels|the controllers built into "power stations"]]. It is also a factor with PWM controllers. |
| |
===== Types of charge controllers ===== | ===== Types of charge controllers ===== |
electrical/solar/charge_controller.txt · Last modified: 2025/02/28 14:09 by frater_secessus