 === solar charging limits === === solar charging limits ===
 +
 +also see [[12v:sg_troubleshooting#must_i_use_the_ps_brand_s_proprietary_solar_panels|this article]] on choosing panels for a SG
  
 Many smaller units have quite restrictive solar input limits.   Many smaller units have quite restrictive solar input limits.  
  
-  * **voltage** - 24Voc is a common voltage limit, effectively limiting one to [[electrical:solar:panels#panel_voltage|12v nominal]] panels. **Input voltage limits must not be exceeded**.+  * **voltage** - 24Voc is a common voltage limit, effectively limiting one to [[electrical:solar:panels#panel_voltage|12v nominal]] panels. **Input voltage limits must not be exceeded**.  Note:  some very large units have high input //minimums//, like 50v
   * **current** limit - 3A is a common input current limit on smaller, less-expensive units.  8A is a common limit on larger units.    * **current** limit - 3A is a common input current limit on smaller, less-expensive units.  8A is a common limit on larger units. 
     * With PWM controllers the max power harvestable will be 3A x [internal battery voltage], which can be as low as 9v.  9v x 3A 27w.  **PWM input current limits must not be exceeded**     * With PWM controllers the max power harvestable will be 3A x [internal battery voltage], which can be as low as 9v.  9v x 3A 27w.  **PWM input current limits must not be exceeded**