This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
opinion:frater_secessus:endamps [2021/05/05 15:37] frater_secessus [WTF does that even mean?] |
opinion:frater_secessus:endamps [2021/05/05 15:54] (current) frater_secessus [WTF does that even mean?] |
||
|---|---|---|---|
| Line 1: | Line 1: | ||
| Note: Flooded, AGM and gel are all types of lead-chemistry battery. | Note: Flooded, AGM and gel are all types of lead-chemistry battery. | ||
| - | ====== How do I know when my lead battery fully charged? ====== | + | ====== How do I know when my lead battery |
| Lead batteries are [[electrical: | Lead batteries are [[electrical: | ||
| Line 10: | Line 10: | ||
| So how do we know when the battery is fully charged? | So how do we know when the battery is fully charged? | ||
| - | **A lead battery is charged when acceptance at Absorption voltage has dropped to a specified value.** | + | **A lead battery is charged when acceptance at Absorption voltage has dropped to a small fraction of its rated capacity.** |
| ===== WTF does that even mean? ===== | ===== WTF does that even mean? ===== | ||
| Line 30: | Line 30: | ||
| - | > has dropped to a specified level. | + | > has dropped to a small fraction of its rated capacity |
| - | This is where the battery monitor shines. | + | Lead battery manufacturers typically specify Absorping until acceptance is some small percentage of [[electrical: |
| - | + | ||
| - | These values can be expressed in different forms but they all mean the same thing: | + | |
| ^ fraction | ^ fraction | ||
| | C/200 - C/100 | 0.5% - 1% of C | 0.005C - 0.010C | | C/200 - C/100 | 0.5% - 1% of C | 0.005C - 0.010C | ||
| + | |||
| + | As you can see the Amps in question are quite small; | ||
| + | |||
| + | |||
| + | ===== putting it all together ===== | ||
| + | |||
| + | Battery X (100Ah) is fully charged when the battery is only accepting 0.5A to 1A at 14.5v.((Totally made-up example. | ||
| + | |||
| + | |||
| Line 45: | Line 52: | ||
| A deep-cyle battery discharged to 50% typically takes [[opinion: | A deep-cyle battery discharged to 50% typically takes [[opinion: | ||
| - | |||
| - | ===== putting it all together ===== | ||
| - | |||
| - | Battery X (100Ah) is fully charged when the battery is only accepting 0.5A to 1A at 14.5v. | ||