====== What will it take to run this load? ====== | ====== What will it take to run this load? ====== | ||
Line 6: | Line 8: | ||
There are several factors: | There are several factors: | ||
+ | - AC vs DC, voltage. | ||
- current (power), in Amps (A) | - current (power), in Amps (A) | ||
- Watt-hours (Wh) ((or Amp-Hours)) (energy) | - Watt-hours (Wh) ((or Amp-Hours)) (energy) | ||
- any [[electrical: | - any [[electrical: | ||
- | - recharging afterward | + | - **recharging afterward** |
And a couple formulas we will use to convert units back and forth: | And a couple formulas we will use to convert units back and forth: | ||
Line 18: | Line 21: | ||
[[opinion: | [[opinion: | ||
+ | |||
+ | |||
+ | ===== AC/DC ===== | ||
+ | |||
+ | Using the US as an example: | ||
+ | |||
+ | * wall outlets are 120v AC (alternating current). | ||
+ | * most vehicles run on 12v DC (direct current). | ||
+ | |||
Line 49: | Line 61: | ||
===== watt-hours ===== | ===== watt-hours ===== | ||
- | Energy use is often done in Watt-hours, although Amp-hours will also work. | + | Energy use ([[electrical: |
Line 55: | Line 67: | ||
+ | Battery chemistries have recommended depths of discharge. | ||
+ | |||
+ | * Lead batts are usually run down to 50%, so we would need at least 28.8Ah of lead to run our 173Wh load for one day (173Wh / 0.5 / 12.0v nominal). | ||
+ | * LiFePO4 batts are usually run down to 20%, so we would need at least 16.9Ah of LFP to run our 173Wh load for one day (173Wh / 0.8 / 12.8v nominal). | ||
+ | |||
+ | Then multiply by the "days of autonomy" | ||
+ | |||
+ | Note that running loads while sufficient charging is active is basically a freebie and does not count against the battery capacity.((it //will// slow down recharging if done during Bulk or and //may// slow down recharging in Absorption stages)) | ||
===== recharging afterward ===== | ===== recharging afterward ===== | ||
+ | |||
+ | This is the part that people often forget (or prefer not to think about) in the planning stage. | ||
If you are recharging LiFePO4 the 173Wh used is basically what you'd need to recharge that battery to its former state of charge. | If you are recharging LiFePO4 the 173Wh used is basically what you'd need to recharge that battery to its former state of charge. |