User Tools

Site Tools


electrical:12v:alternator

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
electrical:12v:alternator [2024/04/26 16:59]
frater_secessus [heat]
electrical:12v:alternator [2024/04/26 17:11] (current)
frater_secessus [sizing the wire]
Line 656: Line 656:
   - use [[electrical:12v:b2b|a DC-DC charger]] to get at least the correct charging voltage   - use [[electrical:12v:b2b|a DC-DC charger]] to get at least the correct charging voltage
   - if charging by relay only, use Crtical size wire to get the most voltage and current to the lead house battery   - if charging by relay only, use Crtical size wire to get the most voltage and current to the lead house battery
 +
 +==== triggering  ====
 +
 +The setup needs to be //triggered// (told when to start/stop) so that it isn't connected all the time.  There are two main methods:
 +
 +  - use of an ON/OFF 12v trigger signal ("D+", "IGN", "ACC").  When the 12v signal is present the charging circuit is operational.  Caveat:  in this kind of setup leaving the key in the ACC position without starting the engine can drain the starter battery. 
 +  - voltage-sensing - 12v is always being provided to the charger.  The batteries are connected when the chassis voltage is above a voltage setpoint (often ≥13.4v) and disconnected when the chassis side measures below  a setpoing (often ≤13.2v).  
 +
 +In some cases both are combined for particular installs.  Ex.  smart alternators. 
 +
 +
 +
  
 ===== alternator hacks ===== ===== alternator hacks =====
electrical/12v/alternator.txt · Last modified: 2024/04/26 17:11 by frater_secessus