It may be desirable to disable alternator charging on-the-fly when stopped in traffic, on hot days, to avoid charging frozen Li cells, | It may be desirable to disable alternator charging on-the-fly when stopped in traffic, on hot days, to avoid charging frozen Li cells, | ||
- | * relays and DC-DC that are triggered solely by D+ can be disabled by a switch on the D+ wire | + | * relays and DC-DC that are triggered solely by D+ can be disabled by a switch on the D+ wire. [[https:// |
* VSR triggered by voltage can can be disabled by a switch on the thin ground wire on the VSR itself.((the VSR requires a ground to make a complete circuit to run internal electronics. | * VSR triggered by voltage can can be disabled by a switch on the thin ground wire on the VSR itself.((the VSR requires a ground to make a complete circuit to run internal electronics. | ||
* some DC-DC can be //derated// by providing a 12v signal to the CURRENT LIMIT terminal ([[electrical: | * some DC-DC can be //derated// by providing a 12v signal to the CURRENT LIMIT terminal ([[electrical: |