User Tools

Site Tools


electrical:12v:alternator

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
electrical:12v:alternator [2022/12/08 13:47]
frater_secessus [voltage-sensing relays]
electrical:12v:alternator [2022/12/08 13:54]
frater_secessus [voltage-sensing relays]
Line 166: Line 166:
         *  [[https://amzn.to/3FgFggW|BlueSea ML-ACR w/manual controll 7622]] - **500A**.  Version of the ML-ACR above with a manual control knob((yellow knob visible on top of housing)) to override isolation or combination if desired.         *  [[https://amzn.to/3FgFggW|BlueSea ML-ACR w/manual controll 7622]] - **500A**.  Version of the ML-ACR above with a manual control knob((yellow knob visible on top of housing)) to override isolation or combination if desired.
       * [[https://amzn.to/2RFaXI7|JayCorp Smart Dual Battery 140A Isolator]]((bonus points to the Jaycorp for printing the connect/disconnect setpoints right on the isolator!))       * [[https://amzn.to/2RFaXI7|JayCorp Smart Dual Battery 140A Isolator]]((bonus points to the Jaycorp for printing the connect/disconnect setpoints right on the isolator!))
-      * Precision Circuits [[https://www.precisioncircuitsinc.com/product/battery-isolation-manager/|BIM]].  Latching relays in **160A** and **225A** versions.  . Disconnects after 1 hour max to prevent overcharging:  "The BIM does not guarantee 100% battery charge, but prevents harmful battery charge levels.((https://www.precisioncircuitsinc.com/wp-content/uploads/2017/06/00-10041-2xx-Battery-Isolation-Manager-Rev7-1.pdf))  //Sig// terminal can use used for [[electrical:12v:self-jumpstarting|self-jumpstarting]] \\ Also see Li-BIM below.+      * Precision Circuits [[https://www.precisioncircuitsinc.com/product/battery-isolation-manager/|BIM]].  Latching relays in **160A** and **225A** versions.  . Disconnects after 1 hour max to prevent overcharging:  "The BIM does not guarantee 100% battery charge, but prevents harmful battery charge levels.((https://www.precisioncircuitsinc.com/wp-content/uploads/2017/06/00-10041-2xx-Battery-Isolation-Manager-Rev7-1.pdf))  //Sig// terminal can use used for [[electrical:12v:self-jumpstarting|self-jumpstarting]]\\ Also see Li-BIM below.
   - DC-DC isolators (aka //[[electrical:12v:b2b|b2b]] isolators//) that boost alternator voltage to [[electrical:12v:charging|more appropriate levels for lead chemistries]] and can do multistage charging. These have [[electrical:12v:b2b|their own page]].   - DC-DC isolators (aka //[[electrical:12v:b2b|b2b]] isolators//) that boost alternator voltage to [[electrical:12v:charging|more appropriate levels for lead chemistries]] and can do multistage charging. These have [[electrical:12v:b2b|their own page]].
  
electrical/12v/alternator.txt ยท Last modified: 2024/03/15 12:27 by frater_secessus