electrical:12v:alternator [2022/12/08 13:47]
frater_secessus [voltage-sensing relays]
electrical:12v:alternator [2022/12/08 13:55]
frater_secessus [lithium-specific]
Line 166: Line 166:
         *  [[https://amzn.to/3FgFggW|BlueSea ML-ACR w/manual controll 7622]] - **500A**.  Version of the ML-ACR above with a manual control knob((yellow knob visible on top of housing)) to override isolation or combination if desired.         *  [[https://amzn.to/3FgFggW|BlueSea ML-ACR w/manual controll 7622]] - **500A**.  Version of the ML-ACR above with a manual control knob((yellow knob visible on top of housing)) to override isolation or combination if desired.
       * [[https://amzn.to/2RFaXI7|JayCorp Smart Dual Battery 140A Isolator]]((bonus points to the Jaycorp for printing the connect/disconnect setpoints right on the isolator!))       * [[https://amzn.to/2RFaXI7|JayCorp Smart Dual Battery 140A Isolator]]((bonus points to the Jaycorp for printing the connect/disconnect setpoints right on the isolator!))
-      * Precision Circuits [[https://www.precisioncircuitsinc.com/product/battery-isolation-manager/|BIM]].  Latching relays in **160A** and **225A** versions.  . Disconnects after 1 hour max to prevent overcharging:  "The BIM does not guarantee 100% battery charge, but prevents harmful battery charge levels.((https://www.precisioncircuitsinc.com/wp-content/uploads/2017/06/00-10041-2xx-Battery-Isolation-Manager-Rev7-1.pdf))  //Sig// terminal can use used for [[electrical:12v:self-jumpstarting|self-jumpstarting]] \\ Also see Li-BIM below.+      * Precision Circuits [[https://www.precisioncircuitsinc.com/product/battery-isolation-manager/|BIM]].  Latching relays in **160A** and **225A** versions.  . Disconnects after 1 hour max to prevent overcharging:  "The BIM does not guarantee 100% battery charge, but prevents harmful battery charge levels.((https://www.precisioncircuitsinc.com/wp-content/uploads/2017/06/00-10041-2xx-Battery-Isolation-Manager-Rev7-1.pdf))  //Sig// terminal can use used for [[electrical:12v:self-jumpstarting|self-jumpstarting]]\\ Also see Li-BIM below.
   - DC-DC isolators (aka //[[electrical:12v:b2b|b2b]] isolators//) that boost alternator voltage to [[electrical:12v:charging|more appropriate levels for lead chemistries]] and can do multistage charging. These have [[electrical:12v:b2b|their own page]].   - DC-DC isolators (aka //[[electrical:12v:b2b|b2b]] isolators//) that boost alternator voltage to [[electrical:12v:charging|more appropriate levels for lead chemistries]] and can do multistage charging. These have [[electrical:12v:b2b|their own page]].
  
Line 228: Line 228:
 The unit supports [[electrical:12v:self-jumpstarting|self-jumpstarting]] but a switch must be installed by the user.  160A and 225A models are available. BB suggests the BIM is recommended for lithium banks >= 300Ah.((https://sprinter-source.com/forums/index.php?threads/68203/post-762424))   The unit supports [[electrical:12v:self-jumpstarting|self-jumpstarting]] but a switch must be installed by the user.  160A and 225A models are available. BB suggests the BIM is recommended for lithium banks >= 300Ah.((https://sprinter-source.com/forums/index.php?threads/68203/post-762424))  
  
-teardown of the Li-BIM can be seen in [[https://www.youtube.com/watch?v=pFd9Uulo9rY|this video]].+An interesting teardown of the Li-BIM can be seen in [[https://www.youtube.com/watch?v=pFd9Uulo9rY|this video]].
 ==== misc ==== ==== misc ====
  
electrical/12v/alternator.txt ยท Last modified: 2024/04/16 11:31 by frater_secessus