electrical:12v:alternator_details [2022/05/20 23:32] frater_secessus [types of alternator] |
electrical:12v:alternator_details [2022/05/20 23:39] frater_secessus [DUVAC] |
===== DUVAC ===== | ===== DUVAC ===== |
| |
Some older RVs come with DUVAC (DUal Voltage Alternator Control)((https://www.countrycoachforums.com/index.php?PHPSESSID=3ggkjl41c5lrkrerduih87oeif&topic=6840.msg34665#msg34665)) setups, which use separate voltage-sense wires for the house bank. | Some older Class A and C RVs came with DUVAC (DUal Voltage Alternator Control)((https://www.countrycoachforums.com/index.php?PHPSESSID=3ggkjl41c5lrkrerduih87oeif&topic=6840.msg34665#msg34665)) setups, which use separate voltage-sensnig wires for the house bank. |
| |
> This Duvac system that Leese Neville came up with was a completely integrated dual battery/isolator setup that was “state-of-the-art” in ’99((diode-based isolators)) but soon was obsoleted by newer better technology.((voltage-sensing relays and DC_DC chargers))((https://www.foreforums.com/index.php?PHPSESSID=bs0n0psbr6rrvd240rv4ijvg1p&topic=33250.msg432529#msg432529)) | > This Duvac system that Leese Neville came up with was a completely integrated dual battery/isolator setup that was “state-of-the-art” in ’99((diode-based isolators)) but soon was obsoleted by newer better technology.((voltage-sensing relays and DC_DC chargers))((https://www.foreforums.com/index.php?PHPSESSID=bs0n0psbr6rrvd240rv4ijvg1p&topic=33250.msg432529#msg432529)) |
| |
| > ...the primary reason for DUVAC is to allow the alternator to "compensate" for the voltage loss (turned into heat) in the old generation **diode-based battery isolators**. There is approximately a .7 VDC loss through the battery isolator. The sense wire/terminal allows voltage on the battery side of the isolator to control the alternator voltage.((https://www.irv2.com/forums/f115/eliminating-the-duvac-system-539048.html#post5772417)) |
| |
| |
{As far as I can tell this was a workaround from when many isolators were diode-based so the alternator could not "see" aux battery voltage on the combined circuit((https://www.foreforums.com/index.php?PHPSESSID=bs0n0psbr6rrvd240rv4ijvg1p&topic=33250.msg300875#msg300875)) -- secessus} See [[https://www.dixie-electric.com/tsb/TSB_704.pdf|this TSB]]. (PDF) | {As far as I can tell this was a workaround from when many isolators were diode-based so the alternator could not "see" aux battery voltage on the combined circuit((https://www.foreforums.com/index.php?PHPSESSID=bs0n0psbr6rrvd240rv4ijvg1p&topic=33250.msg300875#msg300875)) -- secessus} See [[https://www.dixie-electric.com/tsb/TSB_704.pdf|this TSB]]. (PDF) |