electrical:12v:b2b

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
electrical:12v:b2b [2022/11/07 11:06]
frater_secessus [sizing] continuous
electrical:12v:b2b [2022/11/11 15:03]
frater_secessus [Renogy]
Line 245: Line 245:
 [[https://amzn.to/33HJ8ns|{{ https://images-na.ssl-images-amazon.com/images/I/51Hu4-7NxOL._AC_UL160_SR160,160_.jpg}}]] [[https://amzn.to/33HJ8ns|{{ https://images-na.ssl-images-amazon.com/images/I/51Hu4-7NxOL._AC_UL160_SR160,160_.jpg}}]]
  
-  * DC1212 series DC-DC isolators in 20-40((and possibly 60A according to manual nomenclature)) output.  Switched on by ignition circuit on the D+ port.((https://www.renogy.com/content/RNG-DCC1212-20-BC/DCC1212-204060-Manual.pdf)) DIP switches for battery type, Vabs and Vfloat. [[https://www.renogy.com/content/RNG-DCC1212-20-BC/DCC1212-204060-Manual.pdf|manual]] (pdf) [[https://diysolarforum.com/threads/renogy-dcc1212-dc-dc-charger-teardown.10141/|teardown]]  Note:  some versions of the manual [[https://www.reddit.com/r/vandwellers/comments/okfkuk/my_batteries_inverter_and_dcdc_charger_came_in_i/h5899bw/|may have a typo]]+=== DC1212 series === 
-  * DCC-series of voltage sensing b2b chargers in [[https://amzn.to/2NGIP6U|20A]], [[https://amzn.to/33HJ8ns|40A versions]], and [[https://amzn.to/321TSOa|60A]] versions+ 
 + 
 +DC-DC chargers in 20A, 40A, and 60A output.  Switched on by ignition circuit on the D+ port.((https://www.renogy.com/content/RNG-DCC1212-20-BC/DCC1212-204060-Manual.pdf)) DIP switches for battery type, Vabs and Vfloat. [[https://www.renogy.com/content/RNG-DCC1212-20-BC/DCC1212-204060-Manual.pdf|manual]] (pdf) [[https://diysolarforum.com/threads/renogy-dcc1212-dc-dc-charger-teardown.10141/|teardown]]  Note:  some versions of the manual [[https://www.reddit.com/r/vandwellers/comments/okfkuk/my_batteries_inverter_and_dcdc_charger_came_in_i/h5899bw/|may have a typo]].
  
 These chargers appear to have a 3 hour absorption duration.  This is usually insufficient for lead chemistries, but still longer than the 2 hour duration of the DCC series above.  From the manual: These chargers appear to have a 3 hour absorption duration.  This is usually insufficient for lead chemistries, but still longer than the 2 hour duration of the DCC series above.  From the manual:
  
 >> By default, absorption will not exceed 3 hours to prevent overcharging. >> By default, absorption will not exceed 3 hours to prevent overcharging.
 +
 +
 ==== Redarc ==== ==== Redarc ====
  
electrical/12v/b2b.txt · Last modified: 2024/04/12 21:52 by frater_secessus