electrical:12v:b2b [2022/11/11 15:03]
frater_secessus [Renogy]
electrical:12v:b2b [2022/11/11 15:07]
frater_secessus [Renogy]
Line 117: Line 117:
  
 ==== Renogy ==== ==== Renogy ====
 +
 +=== DCC series ===
 +
 +
 [[https://amzn.to/2QYuswm|{{ https://m.media-amazon.com/images/I/41B+GcTmbyS._AC_UY218_.jpg?125}}]] [[https://amzn.to/2QYuswm|{{ https://m.media-amazon.com/images/I/41B+GcTmbyS._AC_UY218_.jpg?125}}]]
  
Line 123: Line 127:
 Note:  a [[https://amzn.to/3fSFDD2|30A combo model]] is also available Note:  a [[https://amzn.to/3fSFDD2|30A combo model]] is also available
        
-=== solar+alternator behavior ===+== solar+alternator behavior ==
 This device's behavior regarding solar+alternator charging is widely misunderstood.  This device's behavior regarding solar+alternator charging is widely misunderstood. 
  
Line 131: Line 135:
 {{http://img.mousetrap.net/misc/renogy2525.jpg}} {{http://img.mousetrap.net/misc/renogy2525.jpg}}
  
-=== charging examples  ===+== charging examples  ==
  
 Using the above information and a theoretical scenario where we have 15A((~250w of panel under excellent conditions)) of solar charging available during the daytime, an alternator capable of delivering 50A, and a bank able to accept 50A of charging: Using the above information and a theoretical scenario where we have 15A((~250w of panel under excellent conditions)) of solar charging available during the daytime, an alternator capable of delivering 50A, and a bank able to accept 50A of charging:
Line 143: Line 147:
 Note:  some have reported better alternator charging performance with the D+ (smart alternator) wire connected, even with plain alternators.  Oversizing cables from the alternator may also help. ((https://www.youtube.com/watch?v=LtIe2rIfpW8))  Note:  some have reported better alternator charging performance with the D+ (smart alternator) wire connected, even with plain alternators.  Oversizing cables from the alternator may also help. ((https://www.youtube.com/watch?v=LtIe2rIfpW8)) 
  
-=== starter battery maintenance behavior ===+== starter battery maintenance behavior ==
  
 > If the service battery is in float charge stage, the starting battery will be charged at the same time. The charging voltage is limited at 13.8V. The charging amperage is limited at 25A.((https://www.renogy.com/content/RBC3050D1S-G1/RBC3050D1S-Manual.pdf)) > If the service battery is in float charge stage, the starting battery will be charged at the same time. The charging voltage is limited at 13.8V. The charging amperage is limited at 25A.((https://www.renogy.com/content/RBC3050D1S-G1/RBC3050D1S-Manual.pdf))
 +
 +
 +
 ==== Kisae ==== ==== Kisae ====
 [[https://amzn.to/3fWJtbH|{{ https://m.media-amazon.com/images/I/81Hke9PigbL._AC_UL320_.jpg?125}}]] [[https://amzn.to/3fWJtbH|{{ https://m.media-amazon.com/images/I/81Hke9PigbL._AC_UL320_.jpg?125}}]]
electrical/12v/b2b.txt ยท Last modified: 2024/04/12 21:52 by frater_secessus