User Tools

Site Tools


electrical:12v:b2b

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
electrical:12v:b2b [2022/11/11 15:07]
frater_secessus [Renogy]
electrical:12v:b2b [2022/12/17 17:02]
frater_secessus [Sterling]
Line 247: Line 247:
  
  
 +The BB1240 has a starter battery maintenance (reverse charging) feature. This might be true for all the 2022 redesigns.
 ==== Renogy ==== ==== Renogy ====
  
Line 261: Line 261:
 >> By default, absorption will not exceed 3 hours to prevent overcharging. >> By default, absorption will not exceed 3 hours to prevent overcharging.
  
 +=== Rego series ===
 +
 +[[https://amzn.to/3E0QZQm|{{ https://m.media-amazon.com/images/I/51pk04meVuL._AC_UY218_.jpg}}]]
 +[[https://amzn.to/3E0QZQm|60A DC-DC]] with different form factor and a configurable USER profile.  Important differneces from teh 1212 line above:
 +
 +  * configurable output current - 60A/50A/40A/30A/20A/10A
 +  * voltage-sense triggering rather than D+
 +  * 10-300min boost duration in USER mode
 +  * 120min boost duration still hard-coded in predefined lead-chemistry modes, BUT will drop to Float if output is less than 3A (ie Absorption termination based on endAmps)
  
 +[[https://store-fhnch.mybigcommerce.com/content/RCB1260DO-100506PR/RBC1260DO-12B_UserManual_A0.pdf|manual]] (pdf)
 ==== Redarc ==== ==== Redarc ====
  
electrical/12v/b2b.txt ยท Last modified: 2024/04/12 21:52 by frater_secessus