electrical:12v:battery_capacity [2017/08/25 21:09]
frater_secessus
electrical:12v:battery_capacity [2017/08/25 21:12]
frater_secessus [Examples]
Line 14: Line 14:
  
 If the manufacturer recommends minimum charging at C/10 the rate should be at or above 20A (200/10). \\  If the manufacturer recommends minimum charging at C/10 the rate should be at or above 20A (200/10). \\ 
-Note: the **usual charge rate** for deep cycle batteries is C/10.  Sometimes manufacturers express that [[electrical:12v:charging|Absorption stage]] is complete((and therefore Float should commence)) when the bank is holding Vabs and charging current has dropped to C/100 or C/200. 
  
 If the manufacturer recommends max //discharge// (load) be 3C the rate should be at or below 600A (3x200). \\  If the manufacturer recommends max //discharge// (load) be 3C the rate should be at or below 600A (3x200). \\ 
  
 +If the manufacturer says that [[electrical:12v:charging|Absorption stage]] is complete when charging current has dropped to C/100 or C/200 then the current to watch for would be 2A (200/100) or 1A (200/200).
  
  