Line 17: Line 17:
 If the manufacturer recommends max //discharge// (load) be 3C the rate should be at or below 600A (3x200). \\  If the manufacturer recommends max //discharge// (load) be 3C the rate should be at or below 600A (3x200). \\ 
  
-If the manufacturers says that [[electrical:12v:charging|Absorption stage]] is complete when charging current has dropped to C/100 or C/200 then the current to watch for would be 2A (200/100) or 1A (200/200).+If the manufacturer says that [[electrical:12v:charging|Absorption stage]] is complete when charging current has dropped to C/100 or C/200 then the current to watch for would be 2A (200/100) or 1A (200/200).
  
 +===== other than 20hr rates =====
  
 +For other than C/20 loads((flooded)):
 +
 +
 +1 Hour = .3 \\
 +2 Hour = .5 \\
 +3 hour = .6 \\
 +4 hour = .65 \\
 +5 hour = .7 \\
 +6 hour = .75 \\
 +8 hour = .8 \\
 +10 hour = .85 \\
 +12 hour = .9 \\
 +16 hour = .95 \\
 +20 hour = 1 \\
 +24 hour = 1.05 \\
 +36 hour = 1.1 \\
 +72 hour = 1.25 \\
 +100 hour = 1.30((vhttps://www.solarpaneltalk.com/forum/off-grid-solar/batteries-energy-storage/11731-peukert-law-batteries-and-you#post11731))