electrical:12v:battery_capacity [2020/05/13 08:49]
frater_secessus [Examples]
electrical:12v:battery_capacity [2020/05/13 08:52]
frater_secessus [C notation]
Line 3: Line 3:
 Battery capacity in Amp-hours is written as **C**. ​ This notation is most useful when talking about charging/​discharging rates.  ​ Battery capacity in Amp-hours is written as **C**. ​ This notation is most useful when talking about charging/​discharging rates.  ​
  
-Note:  most deep cycle manufacturer'​s rate capacity at C/20, due to Peukert effect.+Note:  most deep cycle manufacturer'​s rate capacity at C/20, due to Peukert effect.  In other words, a 100Ah battery will deliver 100A with a 5A load.  See table at bottom for other load levels
  
  
Line 24: Line 24:
  
  
-''​1 Hour = .3 +1 Hour = .3 \\ 
-2 Hour = .5 +2 Hour = .5 \\ 
-3 hour = .6 +3 hour = .6 \\ 
-4 hour = .65 +4 hour = .65 \\ 
-5 hour = .7 +5 hour = .7 \\ 
-6 hour = .75 +6 hour = .75 \\ 
-8 hour = .8 +8 hour = .8 \\ 
-10 hour = .85 +10 hour = .85 \\ 
-12 hour = .9 +12 hour = .9 \\ 
-16 hour = .95 +16 hour = .95 \\ 
-20 hour = 1 +20 hour = 1 \\ 
-24 hour = 1.05 +24 hour = 1.05 \\ 
-36 hour = 1.1 +36 hour = 1.1 \\ 
-72 hour = 1.25 +72 hour = 1.25 \\ 
-100 hour = 1.30''​((https://​www.solarpaneltalk.com/​forum/​off-grid-solar/​batteries-energy-storage/​11731-peukert-law-batteries-and-you#​post11731))+100 hour = 1.30((vhttps://​www.solarpaneltalk.com/​forum/​off-grid-solar/​batteries-energy-storage/​11731-peukert-law-batteries-and-you#​post11731))
electrical/12v/battery_capacity.txt · Last modified: 2020/05/13 08:52 by frater_secessus