electrical:12v:charging [2019/04/11 19:50]
frater_secessus [charge-and-stop]
electrical:12v:charging [2019/04/11 19:54]
frater_secessus [charge-and-stop]
Line 64: Line 64:
   - repeat   - repeat
    
 +**This differs from PWM** because PWM can hold an average voltage by cutting power hundreds or thousands of times a second.  If you make a setpoint for 13.6v it will hold 13.6v as long as sun and [[electrical:12v:loads|loads]] cooperate.  A shunt programmed to charge to disconnect at 13.6v and reconnect at 12.7v will average 13.05v.
 +
 +
 These setpoints may or may not be user-configurable. These setpoints may or may not be user-configurable.
  