Line 10: Line 10:
  
  
-In general, manufacturers of lead chemistries specifiy a charging at [[electrical:12v:battery_capacity|C/10]]; this assumes more charging time than solar power allows.((http://www.cheaprvliving.com/forums/showthread.php?tid=23606&pid=288284#pid288284))  Regularly cycled banks may benefit from firmer charging at C/3.  There may not be a practical maximum charging rate for cycled FLA batteries //when charged from solar// As Sternwake put it when describing a C/1.5 (!) charging scenario, "solar is not instant max output."((http://www.cheaprvliving.com/forums/showthread.php?tid=23606&pid=288284#pid288284))+In general, manufacturers of flooded lead chemistries specify charging at [[electrical:12v:battery_capacity|C/10]] to C/5; this assumes more charging time than solar power allows.((http://www.cheaprvliving.com/forums/showthread.php?tid=23606&pid=288284#pid288284))  AGM are typically charged at C/5 to C/3.  There may not be a practical maximum charging rate for cycled FLA batteries //when charged from solar// As Sternwake put it when describing a C/1.5 (!) charging scenario, "solar is not instant max output."((http://www.cheaprvliving.com/forums/showthread.php?tid=23606&pid=288284#pid288284))
 ===== three stage charging ===== ===== three stage charging =====
  
Line 75: Line 75:
 AGM batteries are kept healthy by: AGM batteries are kept healthy by:
  
-  - vigorous Bulk chargingsometimes greater than solar-only charging can provide.((http://www.cheaprvliving.com/forums/Thread-anyone-familiar-with-Worker-AGM-batteries?pid=97068#pid97068))  Consider augmenting with alternator or shore power charging.+  - vigorous Bulk charging((minimum current of [[electrical:12v:battery_capacity|C/5]] up to C/3)) sometimes greater than solar-only charging can provide.((http://www.cheaprvliving.com/forums/Thread-anyone-familiar-with-Worker-AGM-batteries?pid=97068#pid97068))  Consider augmenting with alternator or shore power charging.
   - long Absorption stages   - long Absorption stages
   - but lower Absorption voltage (to prevent outgassing)   - but lower Absorption voltage (to prevent outgassing)
Line 123: Line 123:
  
  
-A [[http://amzn.to/2gEtVwL|battery waterer]] can make the job easier, and does not require one to judge water level visually.+A [[http://amzn.to/2gEtVwL|battery waterer]] can make the job easier, and does not require one to judge water level visually.  The water "bloops" as it fills and stops blooping when the water is at the correct level
  
 Batteries that are older, in poorer health, or are charged at higher voltages will be "thirstier" Check water levels 1x/month until you know how they behave. Batteries that are older, in poorer health, or are charged at higher voltages will be "thirstier" Check water levels 1x/month until you know how they behave.