This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
electrical:12v:charging [2020/01/13 11:00] frater_secessus [temperature compensation] |
electrical:12v:charging [2020/05/13 12:17] frater_secessus [charging while using the 12v system] |
||
---|---|---|---|
Line 39: | Line 39: | ||
In practice absorption takes longer when the battery has been discharged deeply and shorter when it has not.((http:// | In practice absorption takes longer when the battery has been discharged deeply and shorter when it has not.((http:// | ||
+ | |||
+ | **Mythbuster: | ||
+ | |||
+ | > charge current affects the SOC transition point from bulk to absorption charging - MaineSail((https:// | ||
+ | |||
+ | MaineSail found that | ||
+ | |||
+ | * charging AGM at C/2.5 (max rate) resulted in the battery being 63.3% " | ||
+ | * charging AGM at C/5 (min rate) resulted in the battery being 77.4% " | ||
+ | |||
+ | |||
Some controllers will allow the user to configure the time or ratio of capacity/ | Some controllers will allow the user to configure the time or ratio of capacity/ | ||
Line 149: | Line 160: | ||
**Manual chargers** will not be affected by load as they are controlled by the user. | **Manual chargers** will not be affected by load as they are controlled by the user. | ||
+ | |||
+ | |||
+ | ===== battery voltage while charging ===== | ||
+ | |||
+ | Battery Voltage = Battery Voc((resting voltage)) + (Charge Current x Ri((internal resistance))) | ||