User Tools

Site Tools


electrical:12v:eternal_absorption

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
electrical:12v:eternal_absorption [2020/07/08 15:02]
frater_secessus [dealing with insufficient Absorption]
electrical:12v:eternal_absorption [2020/07/08 15:04]
frater_secessus [workaround]
Line 21: Line 21:
 The Eternal Absorption approach completely forgoes Float stage, forcing the controller to stay in Absorption by **setting Vfloat to Vabs**. This addresses the controller issues above.  It will not address the insolation problem on a given day, but extended Absorption will help reduce damage from previous days of poor harvest.  The Eternal Absorption approach completely forgoes Float stage, forcing the controller to stay in Absorption by **setting Vfloat to Vabs**. This addresses the controller issues above.  It will not address the insolation problem on a given day, but extended Absorption will help reduce damage from previous days of poor harvest. 
  
 +Alternatively, see:  [[electrical:severe_battery_use#increasing_effective_absorption_duration|increasing effective Vabs duration through increased voltage]].
 ===== side benefits ===== ===== side benefits =====
  
electrical/12v/eternal_absorption.txt ยท Last modified: 2021/05/05 11:04 by frater_secessus