Line 11: Line 11:
 ===== common LVD setpoints ===== ===== common LVD setpoints =====
  
-Lead-acid deep cycle batteries ​last the longest with best capacity if they are never cycled more than 50% [[electrical:​depth_of_discharge|Depth of Discharge]]((and fully charged afterwards)). ​ That point is somewhere around 12.20v when rested or very lightly loaded.  ​ +Lead-acid deep cycle batteries are typically discharged ​50% [[electrical:​depth_of_discharge|Depth of Discharge]] ​or less ((and fully charged afterwards)). ​ That point is somewhere around 12.20v when rested or very lightly loaded.  ​
- +
- +
- +
  
 This following chart((http://​www.trojanbattery.com/​pdf/​GEL_Trojan_ProductLineSheet.pdf)) shows DoD vs expected duty cycles. ​ In an offgrid scenario we will assume the bank is cycled every night. ​ If the bank is drained to the usual 50% DoD the bank((under lab conditions)) is predicted to last 1000 cycles, or about 3 years. ​ If the bank cycle is shallower to 20% DoD the bank is expected to last 2500 cycles, or about 7.5 years. ​ If the bank is deeply cycled to 80% DoD the bank is expected to last 500 cycles, or about 1.5 years. This following chart((http://​www.trojanbattery.com/​pdf/​GEL_Trojan_ProductLineSheet.pdf)) shows DoD vs expected duty cycles. ​ In an offgrid scenario we will assume the bank is cycled every night. ​ If the bank is drained to the usual 50% DoD the bank((under lab conditions)) is predicted to last 1000 cycles, or about 3 years. ​ If the bank cycle is shallower to 20% DoD the bank is expected to last 2500 cycles, or about 7.5 years. ​ If the bank is deeply cycled to 80% DoD the bank is expected to last 500 cycles, or about 1.5 years.
Line 42: Line 38:
 |  30|  11.80| ​ 10.62| ​ 9.44| |  30|  11.80| ​ 10.62| ​ 9.44|
 |  20|  11.65| ​ 10.49| ​ 9.32| |  20|  11.65| ​ 10.49| ​ 9.32|
 +
 +
 +Observe and adjust based on your experience with your own system.  ​
 +