electrical:12v:multipoint_charging [2022/08/21 13:53]
frater_secessus [gotchas]
electrical:12v:multipoint_charging [2024/03/29 18:55] (current)
frater_secessus [gotchas]
Line 67: Line 67:
   * Multiple sources may inadvertently exceed the bank's recommended charging current, or your preferred current.  Example:  a lithium battery wants 50A max but each charging source can make 30A.  This might result in overcurrent (60A) during Bulk.     * Multiple sources may inadvertently exceed the bank's recommended charging current, or your preferred current.  Example:  a lithium battery wants 50A max but each charging source can make 30A.  This might result in overcurrent (60A) during Bulk.  
   * theoretical:  low-frequency PWM controllers in parallel with MPPT controllers may confuse the latter with an unstable reference voltage.    * theoretical:  low-frequency PWM controllers in parallel with MPPT controllers may confuse the latter with an unstable reference voltage. 
 +  * some systems may throw a warning if chassis voltage > alternator output voltage((https://www.cruisersforum.com/forums/f14/alternator-solar-panel-conflict-233083.html))
  
  
  