electrical:12v:multipoint_charging [2018/08/26 10:01] frater_secessus [concurrent charging] |
electrical:12v:multipoint_charging [2018/12/12 20:56] frater_secessus [concurrent charging] |
So what happens when multiple chargers are running at the same time? Nothing dramatic, as it turns out. | So what happens when multiple chargers are running at the same time? Nothing dramatic, as it turns out. |
| |
In general, **the charging source with the highest voltage will win**. The only caveat is that if one of your controller uses end-amps to signal the end of Absorption, it may get confused and drop out early.((http://forum.solar-electric.com/discussion/comment/389634#Comment_389634)) | In general, **the charging source with the highest voltage will win**. The only caveat, for advanced users, is if one of your controller uses end-amps to signal the end of Absorption, it may get confused and drop out early.((http://forum.solar-electric.com/discussion/comment/389634#Comment_389634)) |
| |
==== why one source wins ==== | ==== why one source wins ==== |
Most charging involves holding((or trying to reach)) a particular voltage [[electrical:12v:electrical_notation|setpoint]].((current-terminated Absorption excepted for purposes of this discussion)) If a charging source sees the bank voltage is above its own setpoint it thinks the job is done; it sits quietly. | Most charging involves holding((or trying to reach)) a particular voltage [[electrical:12v:electrical_notation|setpoint]].((current-terminated Absorption excepted for purposes of this discussion)) If a charging source sees the bank voltage is above its own setpoint it thinks the job is done; it sits quietly. |
| |
Example. Pretend you have a bank in a van with [[electrical:12v:alternator|alternator charging]] and a large and small [[electrical:solar:panels|solar panel]] on the roof. Each panel has a dedicated [[electrical:solar:charge_controller|charge controller]] because the panels are of wildly different specs. This gives us three charging sources if you are driving down the road at dawn. | Example. Pretend you have a bank in a van with [[electrical:12v:alternator|alternator charging]] and two [[electrical:solar:panels|solar panels]] on the roof. Each panel has a dedicated [[electrical:solar:charge_controller|charge controller]] because the panels are of wildly different specs. This gives us three charging sources if you are driving down the road at dawn. |
| |
The alternator is just a plain alternator and puts out 14.0v all the time. | The alternator is just a plain alternator and puts out 14.0v all the time. |