This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Last revision Both sides next revision | ||
electrical:12v:multipoint_charging [2022/05/25 12:30] frater_secessus [how to make them cooperate] |
electrical:12v:multipoint_charging [2022/08/21 13:53] frater_secessus [gotchas] |
||
---|---|---|---|
Line 63: | Line 63: | ||
Some of these are observed, and some are theoretical. | Some of these are observed, and some are theoretical. | ||
- | * the vagaries of voltage sag across the system may result in the various charging sources seeing slightly different voltages. | + | * the vagaries of voltage sag across the system may result in the various charging sources seeing slightly different voltages |
- | * Multiple controllers set up to trigger Float from endAmps((trailing amps)) may enter float early since they are providing only some of the charging current. | + | * Multiple |
- | * Multiple sources may inadvertently exceed the bank's recommended charging current | + | * Multiple sources may inadvertently exceed the bank's recommended charging current, or your preferred current. |
- | * theoretical: | + | * theoretical: |