Line 26: Line 26:
   * battery bank to fuse panel   * battery bank to fuse panel
   * power distribution runs from one side of the van to the other (bus to bus)    * power distribution runs from one side of the van to the other (bus to bus) 
 +  * DC-DC charging of the house bank from alternator
 +  * sensitive electronics
 +  * inverters running large loads
  
 **Noncritical applications** can accept voltage sag of ≤10%.  With 10% sag 14.4v at the source drops to 13.0v at the other end of the wires.  Some noncritical applications might include: **Noncritical applications** can accept voltage sag of ≤10%.  With 10% sag 14.4v at the source drops to 13.0v at the other end of the wires.  Some noncritical applications might include:
  
-  * isolator charging of the +  * isolator charging of the house bank ([[electrical:12v:alternator#example|details]]), especially when some solar is present 
 +  * MaxxFan control boards are sensitive to overvoltage and may prefer some sag 
  
  